Insulation Calculator

Calculate bags of blown-in insulation for a target R-value, or batts and spray foam.

Insulation type
Units
ft²
R
R-49 to R-60 is common for attics in colder US zones.
R
lb
%
0

    Bag coverage differs by brand. The coverage chart on the bag is the final word.

    Show the formula
    
      

    An insulation calculator traces each attic, rim joists and crawl spaces line back to net square footage.

    Gross square footage misleads. Subtract 15 sq ft for windows and 21 sq ft for doors, split exterior walls, interior walls and garage walls, because their wall cavities carry different R-11, R-13 or R-21 expectations.

    Attics differ. Hitting R-49 or R-30 with loose-fill fiberglass can need up to 60-70% more material by depth than blown-in cellulose, product depending, yet cellulose weighs more, pushing older ceilings toward their drywall sag limit.

    Under 16 CFR 460, every FTC coverage chart shows coverage per bag, installed depth, blow-to depth and settled depth, tested to ASTM standards. Trust manufacturer charts over forum rules, especially where 10-14% settling applies.

    Treat each cost range as a ballpark estimate or high-low estimate. Climate zone, existing insulation, insulation type, 2021 IECC or ENERGY STAR guidance shape the recommended R-value, before rounding to whole bags plus overblow allowance.

    How to Use the Insulation Calculator

    1. Choose what you want to work out. Under Insulation type, pick Blown-in (attic), Batts or rolls or Spray foam. The boxes below change to match.
    2. Pick your units. Keep US for feet and inches, or switch to Metric for meters and centimeters. The default values change with it.
    3. Choose the material. Options: Cellulose or Fiberglass.
    4. Enter your measurements. Fill in the area to insulate, target R-value, existing R-value, bag weight, coverage per bag, foam thickness and kit size. You only see the boxes that apply to the option you picked.
    5. Set the extra. It starts at 10%. Raise it for awkward shapes or rough ground, lower it for simple jobs.
    6. Read the result. The big number is your main answer. Below it you also see area, depth to add and volume. Open Show the formula to see every step with your numbers, or use Copy results to paste them into a message or shopping note.

    Formulas

    First, net area equals length x height minus openings. A 40x8 ft wall gives 320 sq ft; deduct 2 windows at 15 sq ft per window and 1 door at 21 sq ft per door.

    That leaves 269 sq ft of insulated area; divide by package coverage. Spray foam works differently: board feet equals area x thickness in inches, divided by kit yield, and packages get rounded up either way.

    Depth logic first: required depth equals needed R minus existing R, divided by R per inch. Total R-value is additive, so a target R-value of R-49 over existing R-19 batts needs only R-30 more depth.

    Blown-in reverses settling: blow depth equals settled depth divided by 1 - settling. Practitioners shortcut with a settling factor of 1.1 blown fiberglass or 1.2 cellulose times target depth, though the loose-fill published rate wins.

    Blown-in bags: divide attic sq ft by bag coverage, or multiply bags-per-1,000 by area. At 1,000 sq ft for R-49 that’s 22.2 bags; 10% overblow brings 25 bags. Check bag weight against ceiling dead load.

    Measuring the Area and Openings

    Decide early whether you measure gross and subtract, or capture net area directly from measured sections.

    Area deductions stay standardized: 15 sq ft per window and 21 sq ft per door. Openings vary; defaults keep estimates consistent. Skip deductions for uninsulated areas only when they’re already outside your length x height.

    For walls, multiply length by height for each run. Repeated sections, like identical bedroom walls, can be entered once with a quantity, which cuts arithmetic errors. Record framing spacing too, because it decides batt width.

    Attics and floors use the footprint, but only over conditioned space. A garage ceiling below a bonus room counts; the porch roof doesn’t. Insulation placement follows the thermal boundary, not the roofline you actually see.

    Don’t forget attic accesses and doors leading to unheated spaces; hatches need insulation too, usually rigid foam board glued on top. Log them separately so batt or bag quantities aren’t inflated by hatch area.

    R-Value by Climate Zone

    Start with what’s enforced. Your R-value requirement comes from the building department, and code lag means many still enforce the 2015 IECC or 2018 IECC. That enforced minimum for thermal resistance often trails ENERGY STAR.

    Under 2021 IECC Table R402.1.3, ceilings need R-30 in Zone 1, R-49 across Zone 2 and Zone 3, and R-60 from Zone 4 upward, Zones 5-8 included. Older IECC editions accepted R-38 in warmer zones.

    For a bare attic or unfinished attic, the DOE suggests R-49 to R-60 across most climate zones, but diminishing returns arrive quickly. Moving from R-30 to R-49 pays; beyond that, ROI thins in Zones 1-3.

    Wood-frame wall cavities depend on stud size: 2x4 gives 3.5 inches of cavity depth for R-13 or R-15; 2x6 gives 5.5 inches for R-19 or R-21. Zones 6-7 add continuous exterior insulation to exterior walls.

    Location within the assembly matters. Rim joists suit spray foam; a crawlspace or below-grade basement wall may need R-5 continuous. Interior walls and garage walls get R-11 for sound; floors over unconditioned space need more.

    Insulation Type Comparison

    Always compare R-value not inches. By R per inch, fiberglass batt gives R-3.1 to R-3.4, blown-in fiberglass R-2.5, cellulose roughly R-3.2 upward, open-cell foam R-3.5, rigid foam R-5.0, and closed-cell spray foam reaches about R-6.5.

    That’s why R-30 depth varies so dramatically: 4.6 inches of closed-cell, 6 inches of XPS, 8.3 inches of dense cellulose, 9.1 inches of an R-3.3 blown product, or 10.3 inches of loose-fill fiberglass rated R-2.9.

    For R-49 attics it’s stark: 18-22 inches of fiberglass, whose 2.5-3.0 R/inch drops when fluffed, versus 13-15 inches of cellulose at 3.6-3.8 R/inch. Cellulose runs 3 times heavier, so check ceiling load and eave clearance.

    Closed-cell foam is moisture-tolerant and an air barrier, ideal for basement walls, humid climates and air sealing. Fiberglass is non-combustible, a budget option for stud walls, attic floors and DIY new construction, when kept dry.

    Retrofitting existing walls in older homes favors dense-pack cellulose, filling irregular cavities, adding soundproofing; it’s eco-friendly recycled material. Rigid foam over exterior sheathing creates continuous insulation, a high performance fix; batt facing aids moisture resistance.

    Cost

    Judge value by finished performance, not sticker price. Typical installed cost per sq ft: batts $0.75-1.50, blown fiberglass $1.00-2.00, dense-pack cellulose $1.80-3.20, and open-cell foam $2.00-3.50, varying noticeably by region and attic access difficulty.

    Prices swing seasonally, but for DIY material cost, standard R-11 and R-13 batts run about $0.40-0.80, R-15 $0.80-1.60, R-19 $0.90-2.00, and R-21 $1.20-2.50 per square foot, before tape, staples, utility blades, respirators, and protective gear.

    Loose-fill and board material spread wider: blown cellulose $0.50-1.50, blown fiberglass $0.75-2.50, rigid foam board $1-2 per inch, and higher-density panels $2-4. Installed exterior board typically reaches $1.30-2.50 once fastening labor and tape are included.

    DIY marketing often promises 40-60% savings.

    Closed-cell foam is effectively pro only, landing around $2.50-5.00 installed and sometimes $3.00-5.00 in tight urban markets. That premium already includes an air seal; fiberglass needs separate sealing, which narrows the apparent price gap considerably.

    Waste, Settling and Allowance

    Set the default allowance at 0% and raise it only for project conditions. Allowance covers packaging, handling and cutting losses, while rounding to the whole purchase unit already builds in a small hidden buffer.

    Batts see 5-10% waste around wiring, electrical boxes and irregular bays. Splitting a batt around each cable always beats compressing it, but offcuts rarely fit elsewhere, so allowance disappears noticeably faster than most people expect.

    Loose-fill behaves differently. Fiberglass often claims near 0% settling, while labels list 10-14% for many blends and cellulose settling can reach 15-20% early. The manufacturer’s bag chart already folds settling into its initial depth column.

    So settled depth is the real target; your marker must show that settled thickness months later. Getting there means you blow deeper initially. Product guidance decides how deep, never a percentage guessed from forum threads.

    Overblow adds 10% more material for uneven joists and blower inconsistency. The bag count ends in whole bags, and unopened ones usually return without hassle.

    Batts, Rolls and Coverage per Package

    Read the package label, not the aisle sign. It lists R-value, thickness, width, length and pieces per package, multiplying into coverage per package. Brand and product family shift numbers, so verify current coverage each purchase.

    R-13 batts sized for 16-in on-center walls often bundle 100+ sq ft per package, while thicker attic batts like R-38 drop to 40-60 sq ft. Deeper product means fewer square feet inside every compressed bag.

    Rolls behave differently: expect 40-75 sq ft per roll depending on R-value.

    The math stays refreshingly plain: divide net area by coverage, and packages get rounded up. A 269 sq ft wall at 106 sq ft per bundle equals 2.54, so three bundles, with absolutely no exceptions.

    Wall retrofits sometimes skip batts entirely. Dense-pack cellulose typically covers 29-34 sq ft per bag in 2x4 cavities, far less than attic coverage, because density rather than depth drives the bag count inside closed walls.

    Blown-In Specifics (Bags And Depth)

    Read one label row: target R, installed thickness, settled depth, bag rate, and maximum net coverage in sq ft/bag. The rounded coverage column sometimes disagrees with bags per 1,000 sq ft; pick one explicit rate.

    A representative loose-fill fiberglass coverage chart per thousand square feet typically reads: R-13 at 4.8 inches, 5.4 bags, 184.6 sq ft/bag; R-19 at 7 inches, 8 bags, 125; R-30 at 11.1 inches, 13 bags, 77.

    Continuing further up the same chart: R-38 at 14.1 inches, 16.7 bags, 59.9; R-49 at 18.1 inches, 22.2 bags, 45; R-60 at 22.2 inches, 28 bags, 35.8 sq ft/bag, all figured per 1,000 sq ft.

    Notice doubling R never doubles depth neatly, and bag counts climb fast.

    Numbers rarely land clean: chart math might return 36.5 bags or 50.1 bags. Both round up, to 37 and 51 bags, because partial bags don’t exist. Verify against settled-depth markers, never empty bag piles.

    Installation Tips and Prep

    Pre-1980 homes may hide asbestos in vermiculite or lead paint on trim; test first. Drilling closed walls for dense-pack belongs to a professional if either appears.

    Prep the attic: install baffles at each eave bay so soffit vents keep breathing freely, and hold 3 inches clearance from non-IC-rated recessed lights. Seal air gaps around outlets, pipes, wiring and top plates first.

    Staple depth markers every 300 sq ft facing the hatch; the inspector reads them. Permits and inspections run through the building department, and local codes decide which electrical, HVAC or plumbing issues need fixing first.

    Never jam R-19 in 2x4 wall cavities; compression drops it near R-13 performance. Measure accurately around framing, obstructions and plumbing, then add 10% waste. Open stud bays with rolls suit interior soundproofing and garage walls.

    In cold climates, the vapor barrier belongs on the warm side. Basement walls below the frost line take foam board or spray foam, and continuous exterior insulation handles thermal bridging that cavity fill can’t reach.

    Spray Foam

    One board foot equals 1 sq ft at 1 inch thick. So 500 sq ft at 2 inches needs 1,000 board feet, before accounting for overspray, uneven passes, or the thicker buildup near framing members.

    Every kit advertises a theoretical yield, but application conditions cut it.

    Common DIY kits list 180 board feet, 529 board feet or 1,350 board feet. Divide required board feet by realistic yield, then round the kit count up, never down, since partial kits can’t be split.

    Measure cured thickness, not wet passes. Closed-cell expands modestly, so spraying in thinner lifts controls heat buildup and shrinkage. Add an extra allowance of roughly ten percent for ragged edges, tight corners, and missed spots.

    Where foam truly shines is rim joists and air sealing: those joist pockets leak badly, frustrate batts, and need relatively little volume. One small kit often handles an entire basement perimeter within a single afternoon.

    Disclaimers

    Every number this tool returns is a planning estimate, nothing more. Measure twice, then trust the math once.

    The product label always outranks our defaults. Product coverage, kit yields and manufacturer instructions vary between brands, so read the bag before blowing. Real jobs also generate waste, and supplier quantities rarely match exact needs.

    Nothing here confirms code compliance or issues an R-value prescription for your home. Local requirements come from building authorities, not software, and standards shift with each code cycle. Verify targets with your jurisdiction before ordering.

    Some situations demand a site visit from professionals: tricky install conditions, needed air sealing, or ventilation upgrades. Regional pricing also fluctuates seasonally. Judging product suitability for moisture-prone or unusual assemblies requires eyes on the structure.

    Industry Standards Referenced

    Federal labeling starts with the FTC R-value Rule, codified at 16 CFR 460. 460.12 governs package labels, 460.5 sets testing at 75°F mean with a 50°F temperature difference, and 460.17 requires an installer receipt afterward.

    Loose-fill thermal testing follows ASTM C687, plus ASTM C518. ASTM C1374 checks installed thickness, which matters more than people assume.

    Cellulose safety rests on CPSC 16 CFR 1209, testing critical radiant flux and smoldering combustion, while 16 CFR 1404 mandates labeling about clearance from recessed fixtures and flues. Fibers get borate or ammonium sulfate retardants.

    Every coverage chart lists bags per 1,000 sq ft, minimum settled thickness, initial installed thickness, max net coverage, and weight per sq ft. Under 2021 IECC R402.2.1, a raised-heel truss lets R-38 substitute for R-49.

    Ceiling Dead Load

    The ceiling fails before the insulation does. ½ inch ceiling drywall on 24 inch o.c. framing is limited to roughly 1.3 lb/sq ft, and exceeding it invites visible sag between joists within a few seasons.

    Run the arithmetic yourself. A typical cellulose bag weight of 23 lb, applied at 90 bags/1,000 square feet for R-60, produces 2.1-2.3 lb/sq ft. That load quietly overshoots the half-inch limit by roughly sixty percent.

    Fiberglass at the same R-value lands near 0.9 lb/sq ft, comfortably safe. Cellulose is roughly 3 times heavier per cubic foot, which explains why identical R-values can produce opposite structural verdicts on the same ceiling.

    A 5/8 inch ceiling board or sag-resistant board carries more, and tightening framing to 16 inch o.c. helps. Otherwise, choose lighter fill or reduce the target depth.

    Why Bag Count and Depth Are Two Different Answers

    Here’s the truth: you can hit the right depth and still fall short on R-value. Loose-fill density varies by machine settings, so fluffed material looks deep while hiding fewer pounds per square foot than required.

    That’s why the FTC coverage chart specifies bags per 1,000 sq ft alongside thickness. Bag count guarantees mass; buying by depth alone guarantees nothing. Count empties at cleanup, then compare against the chart minimum.

    Cellulose experiences settling of 10-14%, so installed depth exceeds settled depth deliberately. Your blow-to depth must account for that shrinkage. Fiberglass settles less but blows lighter, making overblown thickness a common shortcut among rushed installers.

    Too many bags creates the opposite problem: ceiling overload on thin drywall. Bag count protects R-value, depth confirms coverage, and weight protects the structure.

    Regional Variations

    Northern homeowners chase R-60 while southern codes stop much lower. Recommended R-values from ENERGY STAR often exceed the locally enforced code, so decide whether you’re building to the minimum or to the climate you experience.

    Cold regions introduce ice-dam risk, which makes low eave clearance critical. Install baffles above soffit vents so deep fill never blocks airflow. In a humid attic, trapped moisture degrades cellulose faster than most owners notice.

    Older housing has a ½ inch ceiling on 24 inch o.c. framing, shifting fiberglass vs cellulose choices toward depth vs weight. Recessed lights not IC-rated need 3 inch clearance, a CPSC rule reducing fire risk.

    Product availability differs regionally too; one brand dominates certain distributors. Always defer to the printed bag rather than generic coverage charts, and confirm stock before placing a large order, because substitutions mid-job change every calculation.

    R-11 vs R-13

    Most debates here miss that R-11 has largely been phased out for exterior walls by building code. Today it survives mainly in interior walls for soundproofing, plus retrofits in mild climates where requirements were lighter.

    Dimensionally they’re nearly identical twins: R-11 at about 3.5 inches, many R-13 products near 3.7 inches. That 0.2 inches difference compresses easily into any standard 2x4 cavity, so framing rarely determines which product you choose.

    R-13 delivers roughly 18% better thermal performance at material pricing around $0.50-1.50 per square foot, versus $0.40-0.80 for R-11. On typical wall areas, that $0.10-0.30 difference per square foot pays back quickly through lower bills.

    Even in climate zone 3, the 2021 IECC treats R-13 as a minimum cavity layer paired with continuous insulation. Availability also favors R-13; many suppliers barely stock R-11 anymore, which settles arguments before calculations begin.

    R-13 vs R-15

    Here’s the genuinely counterintuitive part: R-15 doesn’t need deeper framing. It fills the same 3.5-inch cavity as R-13, achieving higher resistance through denser fiberglass or mineral wool that packs more fibers into identical stud space.

    That density costs money, typically 30-50% more cost per square foot for roughly 15% better performance. In 2x4 walls where you can’t add depth, that premium is often the only cavity upgrade available without reframing.

    Contractors in Zones 6-7 lean toward R-15 because every fraction matters in a very cold climate. Still, code there expects continuous exterior insulation too, so R-15 alone rarely satisfies requirements without supplementary layers outside sheathing.

    Mineral wool versions resist fire and moisture better, and they cut cleanly around boxes. For energy efficiency on tight budgets in moderate regions, R-13 combined with careful air sealing often outperforms a carelessly installed R-15.

    R-Value of Drywall and Other Materials

    Technically yes: ½ inch gypsum actually contributes about R-0.45. Practically, it’s a rounding error, though calculators that ignore every layer slightly understate true wall assembly performance.

    Exterior sheathing adds modestly too. Half-inch OSB or plywood lands near R-0.62, varying by density and manufacturer. Combined with drywall, those surfaces barely exceed R-1 total, nowhere near replacing proper cavity insulation in any climate.

    The real story is framing. Wood studs average R-1.25 per inch, so a 3.5-inch member sits near R-4.4. Those studs create weaker paths, interrupting otherwise steady thermal resistance across fifteen to twenty-five percent of walls.

    That’s why rated R-13 insulation between studs never delivers R-13 for the whole wall. Whole-assembly values drop noticeably once framing is averaged in, which is why continuous exterior layers became standard practice in colder regions.

    Continuous Insulation Outside Walls

    The wall’s weakest points are its studs, not its cavities. Thermal bridging through framing leaks heat regardless of cavity R-value, and continuous insulation is the only layer that wraps those bridges from foundation to roof.

    The usual approach installs rigid foam board over exterior wall sheathing, beneath the siding. Just 1 inch of extruded polystyrene foam adds roughly R-5, and it covers every stud face rather than skipping between them.

    Pair that with R-13 batts and the nominal assembly total reaches R-18. More importantly, effective whole-wall performance climbs disproportionately, because the foam directly addresses framing losses that cavity insulation never touched in the first place.

    In new construction within a cold climate, this is often code-required. Plan window and door extensions, longer siding fasteners, and drainage details early; retrofitting continuous foam later means stripping siding, which few owners budget for.

    Wall Projects by Scenario

    Start with the hardest case: a closed-wall retrofit. Without removing drywall, dense-pack blown cellulose through drilled holes is usually the only practical option, filling each stud cavity completely, including around wiring that batts would compress.

    New construction offers freedom. 2x6 framing accepts R-21 batts, while 2x4 walls take R-13 or higher-density products. Choosing framing depth early affects window jambs, wall cost, and long-term heating bills far more than people expect.

    For soundproofing between bedrooms, R-11 or R-13 works fine since thermal energy codes don’t apply. A garage conversion needs exterior-grade values, and insulating garage doors separately with foam board kits noticeably stabilizes adjacent room temperatures.

    Basement finishing demands below-grade thinking: foam against concrete avoids moisture trapped behind fiberglass. For budget planning, always price each wall type separately, because mixed scenarios hide the most expensive surprises in single blended estimates.

    What Impacts the Cost

    Access often moves price more than square footage. An open attic blows quickly, while a finished basement or cramped crawlspace demands slow handwork. 1940s construction frequently adds surprises behind plaster that no estimate fully anticipates.

    Insulation type and installation method set the baseline. Spray foam costs most, cellulose sits mid-range, and fiberglass usually costs least per R-value. Material type also dictates equipment, which strongly affects whether DIY is even realistic.

    Target R-value scales everything. Cold winters push recommendations toward R49-R60 in the attic, and stricter energy efficiency standards or local codes raise minimums. Larger home size multiplies those increments across more square feet of coverage.

    Finally, geography matters. Local pricing, regional prices for materials, and labor rates swing considerably between markets. Labor can exceed half the job total professionally, which is why DIY attic blowing remains popular despite messy cleanup.

    What the Calculator Does and Doesn’t Do

    What you get is a realistic price range, not a promise. Use it to compare materials side by side and test different R-value targets before anyone climbs a ladder or quotes labor in your home.

    The practical payoff: you become a smarter buyer. Walking into contractor conversations with quantities already estimated changes negotiations completely, because you can spot padded bag counts or unrealistic coverage claims almost immediately during the walkthrough.

    It cannot replace a site visit. Tricky install conditions, needed air sealing, ventilation upgrades, hidden moisture issues, old wiring, and steep roof angles all change scope, cost, and sometimes even the material choice itself entirely.

    Think of the result as a starting point for budgeting, not a quote.

    Why Not Generic R-Value per Inch

    Generic R-value per inch figures feel convenient but mislead. Two cellulose brands can differ meaningfully, and loose-fill density changes everything. That’s precisely why this calculator leans heavily on product-specific data wherever manufacturers publish reliable numbers.

    Under FTC labeling rules, package disclosures come from standardized testing. Each individual loose-fill label row ties R-value to thickness, bags, and weight, while package coverage for batts and blankets reflects the actual product dimensions sold.

    Spray foam has its own trap: kit yield depends on temperature, technique, and thickness per pass. Real installation coverage often falls below advertised figures, so plan extra material margin on every closed-cell job.

    Accurate quantity planning requires reading the disclosures, checking local requirements, and keeping product documentation for inspectors. Generic averages work for rough budgeting, but purchasing decisions deserve numbers taken directly from the product you’re actually buying.

    Frequently Asked Questions

    How Much Insulation Do I Need?

    A 40x8 wall has 320 sq ft gross area; deducting two windows 15 sq ft each and a door leaves 269 sq ft net area. Divide by coverage per package, round up, consider 10% waste.

    What R-Value Do I Need?

    Climate zone, assembly, location decide it. Under the 2018 IECC, an attic in Zones 4-8 needs R-49, while exterior walls may need an R-20 cavity or R-13 plus R-5 continuous. Confirm with your building department.

    How Much Does Insulation Cost?

    Fiberglass batts run $0.50-1.50 per sq ft, so 1,200 sq ft of R-13 costs $600-1,800 in materials going DIY. Blown cellulose lands around $1-2, rigid foam board $0.75-2.50, and dense-pack cellulose $2.00-3.50, usually pro only.

    Can I Insulate Over Existing Insulation?

    Measure existing R-value as depth x R per inch, subtract from target, blow loose-fill for the difference. Avoid stacked vapor barriers, keep 3 inch clearance at non-IC-rated recessed lights, and add baffles at soffit vents.

    What Type Of Insulation Is Best?

    Batts suit open wall cavities and floors at rough-in, before drywall. Blown-in owns attics and retrofits, flowing around trusses and wiring with no cutting. Spray foam handles air sealing, irregular spaces; rigid board fits basements.

    How Many Bags of Blown-In Insulation Does a 1,000 Sq Ft Attic Need?

    Divide attic square footage by coverage per bag. A bag chart listing R-49 at 45 sq ft/bag gives 22.2 bags per 1,000 sq ft; round up to 23 bags, or 25 bags with 10% overblow.

    How Deep Should Blown Insulation Be for R-49 or R-60?

    Blown fiberglass at 2.2-2.7 R/inch needs 18-22 inches for R-49; blown cellulose at 3.2-3.8 R/inch needs 13-15 inches. Read the bag chart for initial depth versus settled depth, then staple depth markers for the inspector.

    Does Blown-In Insulation Settle, And Does It Change The Bag Count?

    Fiberglass loose-fill shows negligible settling. Cellulose drops 10-14%, so you blow deeper. The FTC coverage chart’s bags per 1,000 sq ft already account for that; bag count holds, only the depth to blow to changes.

    How Many Sq Ft Does A Roll Or Batt Package Cover?

    R-13 batts for 16-in on-center walls often cover 100+ sq ft per package, while R-38 attic batts hold 40-60 sq ft. Divide net wall area or ceiling area, round up, add 5-10% waste for cuts.

    What Is The Difference Between R-11 And R-13 Insulation?

    R-13 delivers 18% better thermal resistance than R-11 at a price difference of only $0.10-0.30/sq ft. R-11 still suits 2x4 interior walls and soundproofing, but R-13 is the lowest building code minimum for exterior walls.

    Can I Install Wall Insulation Myself?

    With open walls, yes. Fiberglass batts or rolls cut to length press into stud cavities, and DIY can mean 40-60% savings vs professional installation. Closed walls call for dense-pack blown-in, best left to a professional.

    Can Blown-In Insulation Be Too Heavy For My Ceiling?

    Cellulose at R-60 weighs about 2.1-2.3 lb/sq ft, while ½ inch drywall on 24 inch o.c. framing tolerates 1.3 lb/sq ft before it may sag. Fiberglass stays near 0.9 lb/sq ft; otherwise use sag-resistant board.

    Fiberglass Or Cellulose Blown-In Insulation, Which Is Better?

    It’s depth vs weight. Cellulose packs higher R per inch, needs less depth, fills around obstructions, yet runs roughly 3 times heavier and must be kept dry. Fiberglass: light, non-combustible, moisture-tolerant, but needs more depth.

    Does This Calculator Tell Me What R-Value I Need?

    No. It converts a chosen target into material quantity for one product. The required R-value depends on your building assembly, location, applicable requirements, and project conditions, so always confirm that number before running the math.

    Why Does Blown-In Use Bags Per 1,000 Sq Ft?

    Bags per 1,000 sq ft is the manufacturer’s published rate, a direct installation quantity from your selected label row. Dividing by the rounded maximum-coverage column is a reverse calculation inviting rounding differences in bag count.

    What Is A Board Foot Of Spray Foam?

    A board foot equals 1 sq ft of foam 1 inch thick. Spraying 500 sq ft at 2 inches needs 1,000 theoretical board feet, plus an extra allowance, since overspray and trimming always eat yield.